Safe Operating Recommendations
This section provides safety operating recommendations for the QE3 Screen Remote Controller throughout all phases of mission execution.
4 min read · English documentationThis section provides safety operating recommendations for the QE3 Screen Remote Controller throughout all phases of mission execution.
Pre-Operation Checklist (Applicable to Unmanned Platforms Such as Drones, Unmanned Ground Vehicles, Unmanned Surface Vessels, and Humanoid Robots)
Equipment and Connections
- Three-Position Switch Position: Confirm that the switch is not in the unlock position.
- Remote Controller Battery Level: Confirm that the battery has sufficient charge (recommended > 50%).
- Unmanned Platform / Robot Battery Level: Confirm that the device performing the mission has sufficient battery charge.
- Device Connections: Confirm that the QE3 is properly connected to the unmanned platform / robot, data link / data transmission system, ground station, and other required equipment.
- Data Link Video Feed: Confirm that the data link video feed is stable, with no noticeable latency or stuttering.
- Firmware and Parameters: Confirm that the firmware version has been tested and verified beforehand and that no critical parameters have been changed inadvertently.
Environment and Safety
- Weather Conditions: Confirm that the weather is suitable for the operation (including aerial, ground, or surface operations), and avoid extreme weather such as strong winds, heavy rain, and dense fog.
- No-Fly / Restricted-Operation Zones: Confirm that the operating area is not within a no-fly or restricted-operation zone, and complete any required reporting procedures when necessary.
- Obstacles: Check the operating radius for obstacles such as high-voltage power lines, tower cranes, and trees.
- Personnel and Property Safety: Ensure that no unauthorized personnel gather in the operating area, and avoid operating above or in close proximity to densely populated areas.
- GPS / Positioning: If the mission relies on GNSS positioning, confirm that the signal quality is good.
Precautions During Operation (Applicable to Aerial / Ground / Surface Missions)
Operating Practices
- Smooth Operation: Avoid large or sudden control-stick movements and maintain smooth control.
- Monitor Critical Information: Continuously monitor information on the screen, including attitude, altitude, speed, battery level, and signal strength.
- Maintain Visual Range: Keep the device within visual line of sight whenever possible, using the data link / sensor feeds when necessary.
- Low-Battery Response: When the battery level of the device or unmanned platform approaches the warning threshold, prioritize safe actions such as returning, stopping, or docking.
Environmental Monitoring
- Weather Changes: If wind speed increases, rain or snow begins, or other weather changes occur, promptly assess whether to abort the mission.
- Interference Source Monitoring: Watch for potential sources of interference, such as high-voltage power lines and high-power radio equipment, and adjust the route, altitude, or operating method when necessary.
- Altitude and Distance Limits: Comply with local regulatory limits on maximum operating altitude, distance, speed, and other parameters.
Abnormal and Emergency Situations
- Data Link / Remote-Control Signal Loss: Based on the mission configuration, confirm that strategies such as automatic return-to-home and hovering are configured correctly.
-
Low-Battery Warning: Providing a conspicuous warning when the battery level drops below 20% is a recommended strategy,
and a similar approach is recommended on the QE3: return or end the mission as soon as possible after the battery warning is triggered. - Hardware Abnormalities: If an indicator flashes abnormally, the device becomes unusually hot, or the system repeatedly displays errors, abort the mission immediately and investigate the issue.
Post-Operation Inspection and Storage
Equipment Inspection
- Condition Check: Confirm that the remote controller and the controlled unmanned platform show no obvious external damage.
- Remaining Battery Level: If the battery level is still relatively high, adjust it in accordance with the battery storage guidelines.
- Stored Data: Check that critical photos, videos, logs, and other data have been saved properly.
- Equipment Cleaning: Clean the remote controller and the controlled unmanned platform / robot when necessary to prevent the accumulation of dust and moisture.
Data and Mission Review
- Data Backup: Back up critical mission data to a secure location.
- Log Review: Review mission logs as needed (such as flight logs / driving logs / mission logs and alarm logs) to evaluate the mission.
- Issue Records: Record any issues identified during the mission to provide a basis for future improvements.
Storage and Maintenance
- Charging and Storage Charge Level: Adjust the battery to an appropriate charge level before storage, as recommended in the battery safety section.
- Storage Environment: Store the equipment in a dry, cool environment, protected from heavy loads and high temperatures.
- Regular Maintenance: Schedule periodic inspections, cleaning, and calibration based on frequency of use.
Long-Term Use Recommendations
- Review the Safety Section Regularly: Reread this chapter whenever starting a new type of mission or when operating conditions change significantly.
- Firmware and Configuration Management: Retain a stable configuration snapshot for critical missions to avoid unpredictable risks caused by frequent major changes.
- Professional Support: For issues beyond the scope of this manual, contact ROBOSN's official technical support for assistance.